Why Is My Refrigerator Not Cooling?

A refrigerator that runs but does not cool is an urgent fault, because food starts to spoil within hours. The cause is usually one of five things: dirty condenser coils, a failed evaporator fan, a faulty thermostat, a worn door seal, or a compressor problem. This guide explains how to tell them apart.

November 11, 2026

A refrigerator that runs but does not cool is an urgent fault, because food starts to spoil within hours. The cause is usually one of five things: dirty condenser coils, a failed evaporator fan, a faulty thermostat, a worn door seal, or a compressor problem. This guide explains how to tell them apart.

A refrigerator cools by moving heat out of the food compartment, not by making cold. The compressor pumps refrigerant around a loop, the evaporator coil inside the fridge absorbs heat, and the condenser coil at the back or underneath gives that heat off into the room. A fan moves air over both coils. When any part of that loop stops working, the temperature inside the fridge climbs, and the machine often runs constantly trying to catch up.

The pattern of the fault is the clearest clue. If the freezer is cold and the fridge is warm, the cooling system is working but the cold air is not reaching the fridge — usually a fan or a vent problem. If neither compartment is cold, the cooling loop itself has stopped, and the fault is more likely the compressor, the thermostat, or the coils. If the fridge cools some days and not others, the fault is often the thermostat or a fan that stops and starts.

Start with the two checks that need no tools: the condenser coils and the door seal. Coils covered in dust cannot give off heat, and a seal that does not close lets warm room air in all day. Both are common, both are easy to fix, and both are worth ruling out before you call. The sections below work through the causes in the order a technician would check them.

The condenser coils: the first check

The condenser coils sit at the back of the machine or underneath it, behind a grille at the bottom front. Their job is to release the heat the fridge has pulled out of the food compartment, and they can only do that if air can reach them. In most homes the coils collect a thick layer of dust and pet hair within a year, and once they are covered, the fridge has nowhere to put the heat. The compressor runs longer and hotter, and the temperature inside climbs.

Cleaning the coils is a straightforward job. Unplug the fridge, pull it away from the wall, and vacuum the coils with a brush attachment, working from top to bottom. If the coils are underneath, remove the grille at the bottom front and vacuum from there. A coil brush, sold at most hardware stores, reaches between the coils where a vacuum nozzle cannot. Put the fridge back, plug it in, and give it a few hours — a fridge with clean coils often returns to temperature by the next morning.

Freezer cold, fridge warm: the fan and the vents

When the freezer is cold and the fridge is warm, the cooling system is making cold air but the air is not reaching the fridge compartment. On most modern refrigerators, one evaporator coil in the freezer makes all the cold air, and a fan blows some of it through a vent into the fridge. If that fan stops, or the vent is blocked, the freezer stays cold and the fridge warms up.

Open the freezer and listen. You should hear a fan running when the compressor is on, and the sound should stop when you open the fridge door — most machines switch the fan off when the door opens. If you hear nothing, or the fan sounds rough and rattling, the fan motor has likely failed. A fan can also be stopped by ice: if the evaporator coil has iced over, the ice can grow until it touches the fan blades. That points to a defrost fault, and it is covered in the section below.

The thermostat and the temperature settings

The thermostat is the part that tells the compressor when to run, and when it fails, the compressor either never starts or never stops. A fridge that is warm and silent, with no hum from the back, may have a thermostat that is not calling for cooling at all. A fridge that runs constantly and still cannot hold temperature may have a thermostat that is reading wrong, or a control board that is not listening to it.

Before you suspect the thermostat, check the settings. The fridge should sit around 37 degrees Fahrenheit and the freezer around zero. A dial that was knocked, or a digital setting changed by a child, can leave the fridge set too warm without anyone noticing. Set the fridge to its middle setting, wait a day, and check with a thermometer in a glass of water left overnight in the fridge — the water gives a truer reading than the air, which warms every time the door opens.

The door seal: warm air getting in all day

The door seal — the rubber gasket around the door — keeps warm room air out of the fridge. When it wears, tears, or loses its magnetism, warm air leaks in around the edges, and the fridge cannot keep up. A bad seal also lets moist air in, which condenses and freezes on the evaporator coil, so a seal fault can end up looking like a defrost fault. It is one of the most common causes of a fridge that runs constantly and still feels warm.

Test the seal with a piece of paper. Close the door on the paper so half of it sticks out, then pull gently. You should feel resistance all the way around the door. If the paper slides out easily in one spot, the seal is not gripping there. Check the whole perimeter, top and bottom, because a seal can fail in one corner and still look fine everywhere else. Also look for cracks, tears, and mould on the rubber, and check that the door is not sagging on its hinges.

The compressor and the defrost system

The compressor is the heart of the cooling loop, and it is the part no homeowner should try to test or replace. If the compressor does not start, or starts and stops after a few seconds with a click, the fault may be the start relay — a small part that helps the compressor get going — or the compressor itself. A failed start relay is a modest repair. A failed compressor is a major one, and on an older machine it is often the point where the repair-or-replace question comes up. For that decision, the repair or replace guide on this site lays out how to weigh the age of the machine against the cost of the part.

The defrost system is the other half of this section. Every frost-free fridge melts the frost off its evaporator coil on a timer, and if the defrost heater, the defrost thermostat, or the timer fails, frost builds up until it blocks the airflow completely. The signs are a freezer that slowly gets warmer, frost visible on the back wall of the freezer, and a fan that sounds as if it is hitting something. A technician can test the defrost parts and replace the failed one — and the fix is usually far smaller than a compressor.

Massachusetts homes: cold rooms, warm kitchens, and old fridges

Massachusetts homes put refrigerators through two opposite seasons, and both of them matter. In summer, a fridge in a warm kitchen works harder, and a kitchen that reaches into the high seventies on a humid July afternoon will push an older fridge to its limit — especially if the coils are dusty and the seal is tired. In winter, a fridge in an unheated garage or a cold basement can stop cooling altogether, because the compressor oil thickens in the cold and the thermostat thinks the room is already cold enough.

If the fridge is old and the fault is the compressor, the age of the machine matters more than the brand. A fridge that has run for well over a decade in a Massachusetts home has done a full working life, and a compressor fault on a machine that old is the point where most homeowners start looking at a replacement. The refrigerator repair service page on this site explains what a repair visit covers, and the freezer guide covers the matching fault on the freezer side.

Frequently asked questions

Why is my fridge warm but my freezer cold?

The cooling system is working, but cold air is not reaching the fridge. The evaporator fan has usually stopped, the vent between the compartments is blocked, or the damper that opens the vent has failed. Check the vent first, then listen for the fan.

How long can food stay safe in a warm fridge?

Food in a fridge above 40 degrees Fahrenheit should not be kept for more than a couple of hours. Move perishables to a cooler with ice, and throw out anything that has been warm for longer than that — when in doubt, throw it out.

Why is my fridge running all the time?

Dirty condenser coils, a worn door seal, or a thermostat fault are the usual causes. Clean the coils and test the seal with a piece of paper. If the fridge still runs constantly, the thermostat or the control board needs testing.

Can a fridge stop cooling in a cold garage?

Yes. In an unheated space the compressor oil thickens and the thermostat can read the room as cold enough, so the compressor does not run. A fridge in a Massachusetts garage often struggles through January for exactly this reason.

Is it worth repairing a fridge that will not cool?

It depends on the fault and the age of the machine. A fan, a thermostat, or a seal is a modest repair on any machine. A failed compressor on an older fridge is the point where most homeowners weigh repair against replacement.

More from the Blog

Appliance trouble at home?

Call now — describe the problem and get a straight answer about what happens next.

Call (866) 383-1857 →
Call (866) 383-1857